834 research outputs found

    Evaluating Distributed Time-Varying Generation Through a Multiobjective Index

    Get PDF
    In the last decade, distributed generation, with its various technologies, has increased its presence in the energy mix presenting distribution networks with challenges in terms of evaluating the technical impacts that require a wide range of network operational effects to be qualified and quantified. The inherent time-varying behavior of demand and distributed generation (particularly when renewable sources are used), need to be taken into account since considering critical scenarios of loading and generation may mask the impacts. One means of dealing with such complexity is through the use of indices that indicate the benefit or otherwise of connections at a given location and for a given horizon. This paper presents a multiobjective performance index for distribution networks with time-varying distributed generation which consider a number of technical issues. The approach has been applied to a medium voltage distribution network considering hourly demand and wind speeds. Results show that this proposal has a better response to the natural behavior of loads and generation than solely considering a single operation scenario

    Evaluating distributed generation impacts with a multiobjective index

    Get PDF
    Evaluating the technical impacts associated with connecting distributed generation to distribution networks is a complex activity requiring a wide range of network operational and security effects to be qualified and quantified. One means of dealing with such complexity is through the use of indices that indicate the benefit or otherwise of connections at a given location and which could be used to shape the nature of the contract between the utility and distributed generator. This paper presents a multiobjective performance index for distribution networks with distributed generation which considers a wide range of technical issues. Distributed generation is extensively located and sized within the IEEE-34 test feeder, wherein the multiobjective performance index is computed for each configuration. The results are presented and discussed

    Uso de polímetro hidroretentor no plantio de cafeeiros em ambiente protegido.

    Get PDF
    A operação de plantio do cafeeiro em sequeiro é tradicionalmente executada na estação chuvosa, visando proporcionar condições satisfatórias de umidade para o desenvolvimento inicial das mudas no campo. Durante este período a distribuição das chuvas não é regular e a ocorrência de veranicos é freqüente, resultando em morte das plantas por falta de água. Realizou-se este trabalho com o objetivo de avaliar o efeito do polímero hidroretentor (hidrogel) sobre mudas de cafeeiros plantadas em vasos. A pesquisa foi conduzida em vasos, em casa de vegetação, na Fazenda Experimental da Fundação Procafé, Varginha, MG. O experimento consistiu em um fatorial com quatro doses do polímero (0,5; 1,0; 1,5 e 2,0 litros por vaso), dois modos de fornecimento de água e uma testemunha sem água. As mudas foram plantadas em vasos com os polímeros e estes pesados diariamente para monitoramento de perda de água durante 87dias, quando as plantas foram lavadas para medição das variáveis fenológicas. As liberações da água dos vasos para o meio foram maiores na presença do polímero até um período de trinta dias após o plantio, para as dosagens de 1,0 a 2,0 L/vaso do polímero hidratado. Houve aumento crescente na matéria seca das plantas a partir da dosagem de 1,0 L/vaso. Em casa de vegetação, o uso do polímero hidratado no plantio das mudas de café proporcionou maior desenvolvimento das plantas, sendo a melhor resposta obtida para dosagem de 2,0 L

    Analytical results for a Bessel function times Legendre polynomials class integrals

    Full text link
    When treating problems of vector diffraction in electromagnetic theory, the evaluation of the integral involving Bessel and associated Legendre functions is necessary. Here we present the analytical result for this integral that will make unnecessary numerical quadrature techniques or localized approximations. The solution is presented using the properties of the Bessel and associated Legendre functions.Comment: 4 page

    Efeito residual de herbicida pós emergente em mudas de café.

    Get PDF
    O glyphosate é um herbicida sistêmico, não seletivo, aplicado extensivamente em lavouras cafeeiras para o controle de plantas daninhas. Sua ação ocorre pela inibição da atividade da enzima enopiruvil-chiquimato-3fosfato sintase, que participa da rota do ácido chiquímico, nas plantas e nos microorganismos. O presente trabalho teve o objetivo de avaliar a existência de efeito residual de herbicida a base de glyphosate em mudas de Coffea arabica. O experimento foi conduzido em estufa, utilizando vasos de dez litros, com plantio de Brachiaria decumbens ao redor de mudas de café. O herbicida utilizado no trabalho contém 41% glyphosate como ingrediente ativo. Os tratamentos aplicados foram: capina manual; 6,0 e 18,0 L\ha de herbicida aplicados na braquiária; 18,0 L/ha direcionados ao solo; 6,0 L/ha aplicados na braquiaria com posterior adição de gesso(1ton/ha) e um outro com fosfito, todos com duas aplicações do herbicida mediante o replantio da braquiária. Durante a aplicação do herbicida foram utilizadas garrafas pet e sacos plásticos para proteção dos cafeeiros contra a deriva. As avaliações foram realizadas oito meses após a primeira aplicação do herbicida pela determinação da altura das plantas, número e comprimento de ramos plagiotrópicos, e diâmetro do colo das plantas. Foi constatado um menor desenvolvimento das plantas do tratamento com 18,0 l/ha aplicado ao solo, não evidenciando toxidez no cafeeiro por efeito residual de exudação das raízes da braquiária , mas sim, pelo contato direto entre a solução com alta concentração de glyphosate e as raízes dos cafeeiros

    INFLUENCE OF MODELING OF TURBULENCE IN THE FLOW PARAMETERS WITHIN A FOOD OVEN USING THE OPENFOAM®

    Get PDF
    Because of the better flexibility in warming and high production, the continuous furnace tunnel is the better option to the processing of industrialized food products. This study presents a numerical investigation of the effects of RANS turbulence modeling on the main parameters of the air flow inside a continuous oven with indirect heating - velocities, temperatures, streamlines and heat flows by convection and radiation. The geometry and operating conditions used for constructing the model, setting the mesh and initial and boundary conditions were obtained based on values of operating ovens. Modeling consider the hypothesis of air as an ideal gas, incompressible and Newtonian; the equations of continuity, momentum balance and energy in turbulent regime; closing model of two equations κ- ε and radiation model viewFactor. Utilized the free open source software OpenFOAM® for device modeling. The Rayleigh Number of the cavity was used to evaluate the treatment indicated to turbulence. Considering the results obtained, the inclusion of model κ- ε stabilized the velocity fields and temperatures around the average value. In relation to the heat exchanges involved, heat flow by convection on the mat showed negligible compared to the effects of radiation. Due to the discrepancy between the orders of magnitude of convection and radiation, it's difficult the precise evaluation of the first, because small fluctuations in temperature and velocity affect considerably and induce oscillations in their behavior. However, the radiation model attained good approximation the most relevant exchanges, showing a good chance their application in practical cases
    corecore